Yidimu Model Resin
Dental model photopolymer resin
Suitable for LCD / DLP photopolymer resin 3D printing systems.
Yidimu H02 Dental Model Resin
A professional dental model resin for LCD and DLP resin 3D printers, designed for high-detail dental arches, orthodontic models, aligner vacuum forming models and laboratory model workflows.
Dental Model Resin for High-Detail Resin 3D Printing
Yidimu H02 Dental Model Resin is developed for professional dental model production where surface detail, dimensional stability and repeatable printing performance are important. It is suitable for printed dental arches, orthodontic review models, crown and bridge model checks and aligner-related model preparation.
The resin is designed for LCD and DLP photopolymerization printers using 385–405nm light sources. It offers good liquidity for stable resin flow, helping reduce printing separation risks and supporting efficient model printing in dental laboratory workflows.
Product Snapshot
| Product Name | Yidimu H02 Dental Model Resin |
|---|---|
| Resin Type | Photopolymer dental model resin |
| Model | H02 |
| Compatible Printers | Most LCD / DLP 385–405nm resin 3D printers |
| Net Content | 1kg |
| Main Use | Dental models, orthodontic models, vacuum forming model preparation |
Built for Clear Dental Model Details
H02 model resin is intended for professional users who need clean model surfaces, visible anatomical details and stable workflow performance from printing to post-curing.
High Detail Rendering
Designed to present dental model details clearly, helping labs review tooth morphology, arch structure and model edges with better visual clarity.
Smooth Surface Quality
Supports smooth printed model surfaces, reducing the need for excessive manual finishing in routine model production.
Good Liquidity
Good resin flow helps the material reflow quickly during layer printing, supporting stable printing and efficient model formation.
Low Shrinkage
Formulated to help maintain model shape after curing, supporting dimensional consistency in dental model workflows.
Vacuum Forming Support
Suitable for dental models used in aligner vacuum forming preparation, where model strength and surface quality are important.
Wide Printer Compatibility
Compatible with most LCD and DLP resin 3D printers using 385–405nm photopolymerization light sources.
Professional Dental Model Applications
This resin is suitable for model-based dental workflows. It is not positioned as a direct intraoral appliance resin unless confirmed by official product documentation and local requirements.
Dental Arch Models
For upper and lower arch models used in dental lab review, treatment communication and digital dental production workflows.
Orthodontic Model Review
Suitable for orthodontic model evaluation where clear tooth shape, arch contour and surface readability are required.
Aligner Vacuum Forming Models
Can be used for printed models prepared for aligner vacuum forming processes after proper printing, cleaning and UV curing.
Crown and Bridge Model Checks
Helps dental teams create stable model samples for restoration-related review and workflow verification.
Dental Laboratory Production
Suitable for dental labs that need repeatable resin model printing with consistent post-processing routines.
Professional Model Workshops
Supports high-detail resin model printing for workshops serving dental, prototype and presentation model requirements.
Product Specifications and Starting Parameters
Printing parameters should be treated as starting references and adjusted according to printer light intensity, model design and resin tank condition.
Material Properties
| Shore Hardness | 85.7D |
|---|---|
| Flexural Strength | 126MPa |
| Flexural Modulus | 2980MPa |
| Viscosity | 175–235mPa·s |
| Tensile Strength | 55–60MPa |
| Density | 1.14g/cm³ |
Recommended Printing Parameters
| Recommended Light Intensity | 3.1–5mW/cm² |
|---|---|
| Layer Thickness | 0.05mm |
| Normal Exposure Time | 2–3s |
| Bottom Exposure Time | 20s |
| Bottom Layers | 5 layers |
| Recommended Temperature | 18–35°C |
How to Use This Resin in a Dental Printing Workflow
H02 is a rigid dental model resin. It is suitable for printed models that require clear detail, smooth surface quality and stable handling during post-processing. It should be selected when the printed part is used as a model, reference part or forming model rather than a final flexible appliance.
For best results, users should confirm printer compatibility, resin temperature, slicing parameters, model orientation, support strategy, cleaning time and UV curing conditions before batch production.
Before Choosing H02 Resin
- Confirm the printer uses LCD or DLP 385–405nm light source.
- Confirm the part is a model or forming model, not a direct intraoral appliance.
- Prepare a stable cleaning and UV curing process.
- Run test prints before production batches.
- Adjust parameters for your printer and model size.
Resin 3D Printing Workflow
A stable workflow helps dental labs improve model consistency from digital file preparation to final inspection.
Prepare Digital File
Import the dental model file and check model orientation, base thickness and support requirements.
Shake Resin
Shake the resin bottle well before use to help maintain consistent material performance.
Prepare Printer
Clean the resin tank and forming platform. Make sure the tank bottom has good light transmittance.
Print Model
Start from the recommended parameters, then adjust exposure and support settings according to your printer.
Clean Printed Part
Clean with 95% ethanol.
UV Cure and Inspect
Perform air UV curing for 5 minutes, then check the surface and dimensions.
Cleaning and UV Curing Notes
Cleaning
Use 95% ethanol as shown in the product image. Avoid excessive soaking, which may affect surface quality or dimensional stability.
Ultrasonic Bath
The suggested ultrasonic cleaning time is 3–5 minutes. Adjust carefully according to model size and surface complexity.
UV Curing
The suggested air UV curing time is 5 minutes. Actual curing time may vary depending on UV curing equipment and model thickness.
Inspection
After curing, inspect surface finish, model edges, arch shape and fitting areas before using the model in the next workflow step.
Professional Resin Handling Guidance
Resin performance depends on correct storage, careful handling and consistent printer preparation. Keep resin away from unnecessary UV exposure and maintain a clean printing environment.
Storage
Keep the bottle sealed when not in use. Store away from direct sunlight and strong UV light.
Handling
Wear gloves and avoid direct skin contact when pouring resin, removing prints or cleaning the printer.
Printer Care
Clean the resin tank and build platform regularly to reduce print failures and maintain surface quality.
Batch Printing
For production use, confirm parameters with test models before running multiple dental models in one batch.
Frequently Asked Questions
What is Yidimu H02 Dental Model Resin used for?
It is mainly used for dental model printing, including dental arches, orthodontic review models, crown and bridge model checks and models prepared for aligner vacuum forming workflows.
Is this resin compatible with my resin 3D printer?
The product image states compatibility with most LCD and DLP photopolymerization printers using 385–405nm wavelength light sources. Users should still test exposure settings on their own printer before production use.
Can this resin be used for aligner vacuum forming?
The product images mention vacuum forming suitability. In practice, printed models should be fully cleaned, cured and inspected before being used in a forming workflow.
What are the starting printing parameters?
The image provides these reference settings: 0.05mm layer thickness, 2–3s normal exposure, 20s bottom exposure and 5 bottom layers under 3.1–5mW/cm² light intensity. These are starting references and should be adjusted by printer and model.
Is H02 Dental Model Resin for direct intraoral use?
This page positions H02 as a dental model resin. Direct intraoral use should not be assumed unless confirmed by official product documentation, applicable regulations and the intended clinical workflow.
How should printed models be post-processed?
Clean with 95% ethanol, ultrasonically clean for 3-5 minutes, and then cure with UV air for 5 minutes. Users should adjust post-treatment conditions according to model size, equipment, and end use.
Need Resin Parameters for Your Printer?
Contact Yidimu to discuss your dental model workflow, printer type, model size, curing equipment and resin parameter setup. We can help professional users review resin selection and sample printing requirements before production.
Send Your Requirement
- Printer model and light source
- Dental model application
- Expected model size and batch quantity
- Cleaning and UV curing equipment
- Sample printing requirement